Shanghai SOCO Cable Group Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Shen Helen
  • Company Name : Shanghai SOCO Cable Group Co., Ltd.
  • Tel : 86-021-51363115
  • Fax : 86-021-51363330
  • Address : Shanghai,Shanghai,No.1887 Chenqiao Road, Fengpu Industrial Zone,Fengxian District,Shanghai, China
  • Country/Region : China
  • Zip : 201401

EPR insulated PCP sheathed flame retardant marine power cable

EPR insulated PCP sheathed flame retardant marine power cable
Product Detailed
Related Categories:Power Cables
1.Voltage 0.6/1kV 2.Standard: ISO9001 and ISO14001 China Top 10 Wire France BV Certification Specifications

1.Trade mark:SOCO

2.Certificate:ISO,VDE, CE,ROHS 3.Standard: IEC,VDE,BS 4.High quanlity, favourable price

1. Standard

The cable can be produced according to the standard IEC60092-353 and GB/T9331-2008

2. Example

Type

Section Area (mm2)

No. of Core

CVV/DA/SA/NA,CVV80/DA/SA/NA,

CVV90/DA/SA/NA

1-300

1

CVV82/DA/SA/NA,CVV92/DA/SA/NA,

CJV/DA/SA/NA

1-185

2

CJPF/DC/SC/NC,

CJPJ/DC/SC/NC,CJV80/DA/SA/NA

1-185

3

CJPF80/DC/SC/NC,

CJPJ/DC/SC/NC,CJV90/DA/SA/NA

1-95

4

CJPF90/DC/SC/NC,CJPJ90/DC/SC/NC,

CJV82/DA/SA/NA

1-50

5

CJPF96/DC/SC/NC,CJPJ95/DC/SC/NC,CXV/NA/SA/DACXV80/NA/SA/DA,CXV90/NA/SA/DA,CXV92/NA/SA/DACXF/NA/SA/DA,CXFR/NA/SA/DA,CXF80/NA/SA/DACXF90/NA/SA/DA,CXF92/NA/SA/DA,CEF90/NA/SA/DACEF/NA/SA/DA,CEF80/NA/SA/DA,CEF82/NA/SA/DACEF92/NA/SA/DA,CEFR/NA/SA/DA,CEPF90/NC/SC/DCCEPF/NC/SC/DC,CEPF80/NC/SC/DC,CEPF86/NC/SC/DCCEPJ90/NC/SC/DC,CEPFR/NC/SC/DC,CEPF96/NC/SC/DCCEPJ/NC/SC/DC,CEPJ80/NC/SC/DC,CEPJ85/NC/SC/DC CEPJ95/NC/SC/DC,CEPJR/NC/SC/DC

1-2.5

7,10,12,14,16,19,24,27,30,33,37

3. Scope of Application

The cable is suitable for power distribution, transportation, lighting system device on shipboard, off-shore platform or above water building, and it is also available to metallurgical industry, chemical works, power plant and mining industry, etc.

4 . Service condition

(1) The long-time working temperature of conductor of PVC insulated or SBR cable is 70oC

The long-time working temperature of conductor of XLPE insulated or EPR cable is 90oC

 (2) The Max. Temperature of cable under short-circuit (at most 5 seconds)

XLPE or EPR insulation: 250 oC

PVC or SBR insulation: 160 oC

(3) The temperature for laying the cables can not be lower than 0 oC

EPR insulated PCP sheathed flame retardant marine power cable



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.